Chapter 10

Building Services

Introduction

Building services are easily installed within timber frame buildings. Service routings should be designed early to avoid clashes with principle structural elements such as stair trimmers, floor beams and lintels. Installation is very similar to typical masonry homes; however, care and attention is required when drilling and notching structural timber frame elements to accommodate service runs.

Key considerations are:

  1. Design services early in the process and consider carefully fire-stopping requirements
  2. Ensure services routes are planned, use service cavities where needed
  3. Avoid clashes with structural elements
  4. Comply with notching and drilling requirements
  5. Only use trained and competent installers

Overview Building Services

All home warranty providers and certain building service trade associations provide guidance on the installation of building services. All services should be installed by trained, qualified and competent installers, supported, where necessary by third party certification, compliant with building services commissioning requirements.

Plumbing

Timber frame homes are easy to plumb for a wide range of heating and water systems. As with all methods, good site management, installation practices and auditing are important considerations when installing, commissioning and maintaining plumbing systems.

All services should be installed by trained, qualified and competent installers, supported by third party certification (where required) and compliant with building services commissioning requirements.

Electrical

All buildings must comply with electrical installation standards and Institute of Engineering and Technology (IET) safety requirements. As with all methods, good site management, safety consideration, risk assessment, installation practises and auditing are important considerations when installing, commissioning and maintaining electrical systems into homes.

All services should be installed by trained, qualified and competent installers, supported by third party certification (where required) and compliant with building services commissioning requirements.

Ventilation

Timber frame homes are easy buildings in which to install a variety of mechanical ventilation systems. As with all methods, good site management, installation practices and auditing are important considerations when installing, commissioning and maintaining ventilation systems.

It is important to ensure appropriate fire resistance design and fire safety systems (such as fire collars) are used in conjunction with ducts and grille outlets within fire-resistant walls and ceiling locations.

Additional consideration is required when designing and installing MVHR ventilation systems, due to the additional and complex ducting required, access requirements and physical size of the ventilation unit.

All services should be installed by trained, qualified and competent installers, supported by third party certification (where required) and compliant with building services commissioning requirements.

NHBC Technical standards: ventilation systems

Examples of ventilation suppliers’ installation guidance:

Vent Axia Ventilation

Ecoflow Ventilation

Examples of fire protection systems suppliers:

Quelfire

Hilti

Tenmat

Low & Zero Carbon Renewable Technologies

All buildings fitted with low and zero carbon technologies are required to comply with Micro-generation Certification Scheme (MCS) standards and IET requirements. As with all methods, good site management, safety considerations, risk assessment, installation practices and auditing are important considerations when installing, commissioning and maintaining LZCT generation systems, such as Solar PV.

They apply to:

  • Solar PV (e.g. MCS 005)
  • Solar thermal hot water
  • Heat pumps (air source and ground source – e.g. MCS 007)
  • Biomass boilers
  • Battery storage
  • Wind turbines
  • Micro-CHP (Combined Heat & Power)

 

Key requirements include:

  • Design suitability for the property
  • Correct installation procedures
  • Commissioning and handover processes
  • Ensuring system performance estimates are realistic and disclosed to the customer

 

All LZCT services should be installed by trained, qualified and competent installers, supported by third party certification (where required) and compliant with building services commissioning requirements.

Gas Installations

All buildings are required to comply with the Gas Safety (Installation and Use) Regulations 1998 (GSIUR). As with all methods, good safety management, risk assessment, installation practices and auditing are important considerations when installing, commissioning and maintaining gas systems in homes.

Only Gas Safe registered engineers can legally carry out installation, maintenance, and repair of gas appliances and pipework.

Appliances must be:

  • Safe for use
  • Properly installed
  • Appropriately maintained

 

For timber frame particular care should be made to ensure appropriate ventilation, leak detection, use of flexible pipework/joints at differential settlement/movement areas and final inspection, before closing in gas services

Notching & Drilling

Service routings should be designed early to avoid clashes with principal structural elements such as stair trimmers, floor beams and lintels. Installation is very similar to a masonry home. Care and attention is required when drilling and notching structural timber frame elements to accommodate service runs. Almost all modern timber frame buildings use I-joists or open metal web joists. It is easy to introduce services into floors constructed using both of these products.

Guidance is available to confirm the extent to which timber studwork, rails, rafters and floor joists can be notched or drilled, to avoid undermining their structural capacity.

Key considerations are:

  1. Early design of service routes must be applied
  2. Avoid routes that clash with principal structural elements such as stair trimmers, beams or lintels.
  3. Run services parallel with joists or within boxing below the fire protection line
  4. Use service cavity on walls, in front of the fire protection line
  5. Use engineered floor joists, which can accommodate service installations easier
  6. Only notch or drill in compliance with guidance
  7. Never notch or drill near a bearing point
  8. If in doubt, check: don’t proceed if unsure